3D Profile Measuring

Flash Dimension Measuring QM Series

Model: QM
FlashMeasure 一键闪测仪,一机双模态(远心 2D + 线激光 3D 同轴双 Z),一次装夹同时输出尺寸与三维轮廓,覆盖五金、3C、锂电、新能源、医疗、半导体与农业分选等多行业。
PRODUCT FEATURES

Product Features

⚡

Coaxial dual-Z dual-modality

Telecentric 2D + line-laser 3D, two results per fixturing

🎯

Sub-micron accuracy

Metrology-grade repeatability with traceable calibration

🚀

One-click measure

Place-and-measure, line-speed batch throughput

🔗

Five-protocol data

MES / OPC UA / Q-DAS / MQTT / WebSocket to the line

📊

SPC statistics

Real-time capability analysis & traceable reports

🏭

Multi-industry packs

Hardware / 3C / Li-ion / NEV / medical / semiconductor / agri

Dual-modality, two results in one fixturing

Telecentric 2D imaging and line-laser 3D profile share one coordinate system, so one machine yields both a dimension report and a 3D form — collapsing the budget of “two devices” into one.

One-click measure, batch throughput

Place-and-measure with one-click start, auto-recognition and batch scheduling; the repeat cycle can reach line speed, ideal for incoming inspection and full inspection.

Data to the end — more than a report

A five-protocol data layer (MES / OPC UA / Q-DAS / MQTT / WebSocket), with a calibration-certificate system and SPC, pushes measurement straight into work orders, error-proofing and traceability — making the instrument a data node, not an island.

One algorithm stack, three product families

The geometry core (Umeyama / CUDA registration, dual-Z optics) powers FlashMeasure and extends into vision positioning (robot guidance) and 3D inspection; the comms layer extends into a quality-execution platform and dashboards.

FlashMeasure One-click Measuring Instrument One-click measuring instrument (benchmark reference) Vision dimension measuring machine (benchmark reference)
SPECIFICATIONS

Technical Specifications

ParameterSpecification
Modality2D imaging + 3D line-laser profile (coaxial dual-Z)
RepeatabilitySub-micron Z (by model; U3 station ~0.4μm)
RangeDesktop to 500×400mm large field (by model)
InterfacesMES / OPC UA / Q-DAS / MQTT / WebSocket
SoftwareHB-MES / HB-Guide / HB-Inspect packs
IndustriesHardware, 3C, Li-ion, NEV, medical, semiconductor, agri
Price bandRMB 20k ~ 480k (by SKU)
FAQ
Frequently asked questions about this product, with citable answers.
Can the equipment integrate with my MES or PLC?

Yes, and it is standard capability rather than a paid add-on. The host software provides multiple interfaces: TCP sockets, Modbus TCP and discrete I/O handshaking for PLCs, and REST APIs or direct database access for MES, ERP and QMS. Work orders, serial numbers, measurement results, verdicts and reject reasons can all be exchanged bidirectionally. The process is: agree on the interface and field mapping, commission in a test environment, validate with real work orders, then switch over on site. If the counterpart system only supports file exchange (CSV/XML), polling a shared folder is also supported.

What are the measurement accuracy and repeatability?

One-click flash measuring devices typically achieve micron-level positioning accuracy, but repeatability matters more because it determines whether the equipment can hold your tolerance band reliably. A practical rule is that repeatability should be better than one fifth of the tolerance band, and one tenth for critical characteristics, with margin left for temperature, fixturing and surface condition. Accuracy figures only mean something when tied to measuring range, ambient temperature and calibration method; a single unqualified number is misleading. In the technical agreement we state the accuracy and repeatability for your working conditions and define the acceptance method.

What installation space and power supply does the equipment need?

Four conditions should be confirmed before installation: the machine footprint plus service access, allowing maintenance clearance around the unit; table load capacity and levelness, with precision equipment placed on a separate foundation or vibration-isolated table away from presses and compressors; power, typically single-phase 220V with a stabilized or isolated supply and reliable earthing; and environment, avoiding direct sunlight and air-conditioner drafts because temperature and humidity swings directly affect repeatability. With a formal quotation we provide the installation conditions checklist and a site layout drawing for preparation.

Do I need dedicated fixtures?

It depends on part geometry and locating requirements. Regular, flat, orientation-independent parts usually need only a simple locating block, which is cheap and quick to change over. Irregular or rolling parts, parts needing multi-face measurement, and cases where repeat locating accuracy must approach the equipment's own repeatability call for a dedicated fixture, otherwise locating error eats directly into the measurement margin. Fixtures can be built in-house or designed and manufactured by us; determine this during the trial stage so you do not discover handling problems only after the machine arrives.

Does it support fast changeover between multiple part models? How long does it take?

Yes. Measurement programs are stored as product configuration files, so changeover means calling up the right program, usually taking seconds to tens of seconds depending on whether the fixture changes. The system can store an unlimited number of product programs and call them automatically by work order, barcode or PLC signal, avoiding manual program selection errors. With barcode scanning, an operator simply scans the part or work order to switch both program and acceptance criteria. This is one reason we use a configuration-driven architecture: adding a product requires only a new or adjusted configuration, not a code change.

Which communication protocols are supported (TCP, Modbus, REST)?

We support both shop-floor and IT-level integration. Shop floor: custom TCP socket messages, Modbus TCP (configurable master or slave), discrete I/O handshaking and serial ports (RS232/RS485). System level: RESTful APIs with JSON, direct database access, shared-folder file exchange (CSV/XML) and WebSocket real-time push. If your line uses fieldbuses such as OPC UA or PROFINET, these can be connected through a gateway or middleware, and we provide interface documentation to assist. All interfaces are configuration-driven, so no separate software build is needed per protocol.